| Ranges in bar |
0…2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400 -1 / 3, -1 / 5, -1 / 9, -1 / 15, -1 / 24 |
| Application |
Constant load: up to full scale value Alternating load: 0.9 × full scale value Short time: 1.3 × full scale value |
| Case |
stainless steel 1.4301 with blow-out plug for pressure build-up protection safety separation wall between measuring element and dial |
| Bezel |
CrNi steel |
| Window |
laminated glass |
| Sensor element |
stainless steel measuring cell, thin film technology |
| Wetted parts |
CrNi steel O-ring Viton (FKM) |
| Pressure connection |
SW 22, CrNi steel |
| Connection thread |
G 1/2 B |
| Repeatability |
< 0.05 % of full scale value |
| Stability per year |
< 0.2 % full scale value in rated conditions |
| Electrical connection |
junction box with screwing Pg 13.5 |
| Power supply |
12…30 VDC (14…30 VDC for output 0…10 V) |
| Power consumption |
Output 4…20 mA: signal current Voltage output 8 mA |
| Permissible load |
Current 2-wire: Rmax = ((UB-UBmin) / 0.02) Ohm Voltage: Rmin = 10 kOhm |
| Temp. comp. range |
-28…82 °C |
| Temp. influence |
0.3 % / 10 K, zero point and measuring element (0…50 °C) |
| Response time |
< 1 ms (from 10 % to 90 % of full scale value) |
| Temperatures |
Medium: -20°C to 80°C Ambient: -25°C to 60°C |