| Accuracy |
0.35 % of full scale value |
0.25 % of full scale value |
| Ranges |
in mbar: 0…60, 100, 160, 250, 400, 600 in bar: 0…1, 1.6, 2.5, 4, 6, 10, 16 |
| Overload limit |
up to 250 mbar → 2 bar from 400 to 600 mbar → 4 bar from 1 to 1.6 bar → 7 bar 2.5 bar → 15 bar from 4 to 6 bar → 25 bar from 10 to 16 bar → 40 bar |
| Sensor element |
Capacitive ceramic sensor |
| Case |
CrNi steel |
| Wetted parts |
CrNi steel, ceramic Al₂O₃ |
O-ring Viton (FKM) |
| Pressure connection |
Hexagon 27 mm, CrNi steel |
| Connection thread |
G 1 1/2″ |
| Electrical connection |
Plug according to DIN 43650 with junction box |
| Power supply |
12…36 VDC |
| Power consumption |
Output 4…20 mA < 30 mA |
Voltage output < 15 mA |
| Temp. comp. range |
-20…80 °C |
| Temp. influence |
±1.5 %, zero point and span |
| Protection type |
IP 65 to EN 60529 / IEC 529 |
| Temperatures |
Medium: -25°C up to 125°C Ambient: -25°C up to 85°C |
| Weight |
0.46 kg |